NOTES:

1. This is the maximum allowable reading for all Digital and Electronic telephone cable runs except if connecting an HDSS

console to Circuits 7 and 8 of a PEKU—then the maximum cable restriction is 20 ohms, not 40 ohms.

2. The green-red, black-yellow and white-blue measurements should be within 10% of each other.
3. Nominal voltage—within the limits of

±

26.3 ~

±

27.8 VDC while under AC power, polarity depending on voltmeter lead

placements.

Pair

TABLE C

(ELECTRONIC TELEPHONE CABLES)

STATION CABLE CONTINUITY

CHECK USING OHMMETER

1

1

1

1

1

2

3

3

3

3

3

3

3

3

Wire

T

R

T

R

T

T

T

T

R

T

R

T

R

T

Color

Green

Red

Green

Red

Green

Black

White

White

Blue

White

Blue

White

Blue

White

FROM

Pair

2

2

2

2

1

2

3

1

1

1

1

2

2

2

Wire

T

T

R

R

R

R

R

R

R

T

T

T

T

R

Color

Black

Black

Yellow

Yellow

Red

Yellow

Blue

Red

Red

Green

Green

Black

Black

Yellow

TO

Resistance

open

open

open

open

40 ohms

40 ohms

40 ohms

open

open

open

open

open

open

open

1

1

1

Pair

TABLE E

(DIGITAL TELEPHONE CABLES)

STATION CABLE CONTINUITY

CHECK USING OHMMETER

1

1

1

1

1

2

Wire

T

R

T

R

T

T

Color

Green

Red

Green

Red

Green

Black

FROM

Pair

2

2

2

2

1

2

Wire

T

T

R

R

R

R

Color

Black

Black

Yellow

Yellow

Red

Yellow

TO

Resistance

open

open

open

open

40 ohms

40 ohms

1

1

Pair

TABLE D

(DIGITAL TELEPHONE CABLES)

STATION CABLE CONTINUITY

CHECK USING VOLTMETER

1

1

1

1

1

2

Wire

T

R

T

R

T

T

Color

Green

Red

Green

Red

Green

Black

FROM

Pair

2

2

2

2

1

2

Wire

T

T

R

R

R

R

Color

Black

Black

Yellow

Yellow

Red

Yellow

TO

VOLTAGE

0

24

24

0

24

24

3

3

3

3

Pair

TABLE B

(ELECTRONIC TELEPHONE CABLES)

STATION CABLE CONTINUITY

CHECK USING VOLTMETER

1

1

1

1

1

2

3

3

3

3

3

3

3

3

3

Wire

T

R

T

R

T

T

T

T

R

T

R

T

R

T

R

Color

Green

Red

Green

Red

Green

Black

White

White

Blue

White

Blue

White

Blue

White

Blue

FROM

Pair

2

2

2

2

1

2

3

1

1

1

1

2

2

2

2

Wire

T

T

R

R

R

R

R

R

R

T

T

T

T

R

R

Color

Black

Black

Yellow

Yellow

Red

Yellow

Blue

Red

Red

Green

Green

Black

Black

Yellow

Yellow

TO

VOLTAGE

3

24

24

24

24

0

0

0

0

0

0

0

0

0

0

0

3

3

3

3