background image

REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES

SECTION 100-816-600

MARCH 1993

-47-

TABLE RM-AT

PROGRAM 46-6 ~ 8

TOLL RESTRICTION ALLOWED/DENIED OFFICE CODES ASSIGNED BY CLASS

ACTION

STEP

DISPLAY/PRINTOUT

1

>MODE PROG

P

Enter Program Mode
At the >MODE prompt, enter

P R O G CR

.

2

P 46

P46

Enter Program Number 46

6

Press

CR

.

Refer to the System Record Sheet and enter the office code or
office code group. Single . Group

*

.

Press

SPACE

to enter more codes.

P46 X Y

ALLOW –

or DENY

7

Press

SPACE

to temporarily store data. Press

SPACE

when

completed.

P46

8

Continue returning to step 3 until all data input is completed for
this program.

To Exit this Program
Press

# # CR

.

P46 ##

P

3

Enter class number (1 ~ 4).

P46

Class Number (X)

4

Enter

6

,

7

, or

8 SPACE

.

P46

6

7

8 SPACE

— to add codes to memory (allowed).

— to delete codes from memory (deny).

— to display codes in memory (allowed codes).

6, 7, or 8 (Y)

5

Advertising