REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-47-
TABLE RM-AT
PROGRAM 46-6 ~ 8
TOLL RESTRICTION ALLOWED/DENIED OFFICE CODES ASSIGNED BY CLASS
ACTION
STEP
DISPLAY/PRINTOUT
1
>MODE PROG
P
Enter Program Mode
At the >MODE prompt, enter
P R O G CR
.
2
P 46
P46
Enter Program Number 46
6
Press
CR
.
Refer to the System Record Sheet and enter the office code or
office code group. Single . Group
*
.
Press
SPACE
to enter more codes.
P46 X Y
ALLOW –
or DENY
7
Press
SPACE
to temporarily store data. Press
SPACE
when
completed.
P46
8
Continue returning to step 3 until all data input is completed for
this program.
To Exit this Program
Press
# # CR
.
P46 ##
P
3
Enter class number (1 ~ 4).
P46
Class Number (X)
4
Enter
6
,
7
, or
8 SPACE
.
P46
•
6
•
7
•
8 SPACE
— to add codes to memory (allowed).
— to delete codes from memory (deny).
— to display codes in memory (allowed codes).
6, 7, or 8 (Y)
5