CHART NO. 3

STATION DIAL TONE FAULTS

START

Check station wiring

per paragraph 8

of this section.

Repair if necessary.

Is the fault

cleared?

3-1

END

YES

Is

the

faulty station on a

replaceable station

PCB?

3-2

Replace the PCB

and retest

3-3

Replace the DK8 or

DK16 Base KSU and

initialize the system

(Prog: 90, 92, 03).

Is the

fault

cleared?

3-7

NO

Are the

faulty station(s) only

in the DK16 expansion

unit?

Retest.

Change the expansion

unit and retest.

3-5

YES

Is the

fault

cleared?

YES

3-6

END

Go to

3-4

Call your technical

support group.

NO

YES

NO

NO

NO

3-8

YES

Is the fault

cleared?

NO

YES

3-4

Replace the defective

unit and return it to the

repair center

Go to

3-4

Replaceable Station

PCBs

DK8: QCDU and

QSTU

DK16 Base: KSTU
DK16 Expansion:

KCDU, PDKU,
PEKU, PESU