Toshiba Strata DK8 User Manual

Page 262

Advertising
background image

REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993

-12-

acters represent a program group or a particular
program, i.e., ALL, 03, 04, 10, 39, etc. For a printout
example, see Figure 6.

NOTE:
Programs are output only in the groups indi-
cated. To print out or review a program not
included above, use Program Mode proce-
dures.

9.04 Speed Dialing Dump: While in the dump
mode (see Paragraph 7), enter “REP” and two or
three characters and press

CR

. The characters

represent the speed dialing codes for either an
individual station,

A L L

(all stations and system

data)

S Y S

(system data only).

9.05 LCD Messages Dump: While in the dump
mode (see Paragraph 7), enter “MSG” and two or
three characters and press

CR

. The characters

represent stored messages for either an individual
station,

A L L

(all stations and system data) or

S Y S

(system data only). For a printout example,

see Figure 7.

9.06 Tables provide a quick reference to the step-
by-step procedures to output the appropriate data.

10 TEST MODE

10.00 General

10.01 The remote test mode (see paragraph 7)
can be used to test STRATA DK8 or DK16 stations

and CO line circuits from an off-site location.
10.02 This testing function is accomplished by
accessing stations from the remote terminal, and
activating various buttons on digital and elec-
tronic telephones to make telephone calls, set
function buttons, change the system time and
date, etc. (see Figure 8 and Tables RM-BS ~ BV).

IMPORTANT!

Any digital or electronic telephone button
can be activated from the remote terminal
at any time while in the Test Mode (even
while the end user is using the telephone).
Therefore, caution must be used to prevent
service interruption or interference. The
Test Mode provides status tests to check
whether or not a station or CO line is in use.
The status checks should always be made
before performing other tests (see Table
RM-BS).

10.10 CO Line Testing

10.11 To test CO line transmission, two or three
CO lines must be available at the remote site (see
Figure 8 and Table RM-BU).

10.12 CO line testing is accomplished by using all
of the following two methods:

1) Establish a talk path between the two remote

stations (B & C) via a CO-to-CO connection
through STRATA DK8 or DK16.

81

81

81

81

81

81

81

00

01

02

03

04

05

06

8 1

11111111

00000000

00000000

00000000

00000000

00000000

00000000

1:SELECT(LED ON)

CO LINE

NUMBERS

STATION PORT NUMBER

PROGRAM NUMBER

CO LINE 01

CO LINE 08

FIGURE 7
SAMPLE PRINTOUT OF SYSTEM MESSAGES

FIGURE 6
DATA DUMP PRINTOUT EXAMPLE

>MODE DUMP

D MSG SYS

SYS M60 OUT TO LUNCH

SYS M61 IN A MEETING

SYS M62 CALL

SYS M63 BACK AT

SYS M64 RETURN ON

SYS M65

SYS M66

SYS M67

SYS M68

SYS M69

D