Toshiba Strata DK8 User Manual

Page 201

Advertising
background image

8-7

INSTALLATION-WIRING DIAGRAMS

SECTION 100-816-208

MARCH 1993

FIGURE 8-2
DK8 MDF WIRING TO KSU AMPHENOL STATION AND RELAY CONNECTIONS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

W-BL

BL-W

W-O

O-W

W-GN

GN-W

W-BR

BR-W

W-S

S-W

R-BL

BL-R

R-O

O-R

R-GN

GN-R

R-BR

BR-R

R-S

S-R

BK-BL

BL-BK

BK-O

O-BK

BK-GN

GN-BK

BK-BR

BR-BK

BK-S

S-BK

Y-BL

BL-Y

Y-O

O-Y

Y-GN

GN-Y

Y-BR

BR-Y

Y-S

S-Y

V-BL

BL-V

V-O

O-V

V-GN

GN-V

V-BR

BR-V

V-S

S-V

26

1

27

2

28

3

29

4

30

5

31

6

32

7

33

8

34

9

35

10

36

11

37

12

38

13

39

14

40

15

41

16

42

17

43

18

44

19

45

20

46

21

47

22

48

23

49

24

50

25

BRIDGING
CLIPS

TO BASE UNIT (P5)
W/FEMALE CONNECTOR

25-PAIR CABLE W/MALE AMP CONNECTOR

66M150 SPLIT BLOCK

CIRCUIT 2 TO DKT2

4

OR PDIU-DS

CIRCUIT 3 TO DKT3

4

OR PDIU-DS OR
DDCB

CIRCUIT 4 TO DKT4

4

OR PDIU-DS OR
DDCB

CIRCUIT 6 TO DKT6

5

OR PDIU-DS

CIRCUIT 7 TO DKT7

5

OR PDIU-DS

CIRCUIT 5 TO DKT5

5

OR PDIU-DS

(-) T1 (VOICE/DATA)

4

(GND) R1 (VOICE/DATA)
(-) PT1 (ADD, POWER)
(GND) PR1 (ADD. POWER)

T2

R2
PT2

PR2
T3

R3
PT3
PR3
T4
R4
PT4
PR4
T5
R5
PT5
PR5
T6
R6
PT6
PR6
T7
R7
PT7
PR7

NOT USED

JACKETED TWISTED PAIRS
24AWG (1 OR 2 PAIR, SEE NOTE 2)

STATION CABLING

GN

6 5 4 3 2 1

Y

BL

R

BK

W

3 4

R1

PT1

T1

PR1

2

5

PR TR PT

RJ11

DIGITAL
TELEPHONE (DKT 1)
(WITH OR WITHOUT ADM,
PDIU-DI/PDIU-DI2)

MODULAR
CORD

GND

PR

(-)

T

GND

R

(-)

PT

STD TEL

3

CIRCUIT 1

NOT USED

STD TEL
CIRCUIT 2
OR BGM

NOT USED

R1
T1

R1
T1

CIRCUIT 8 TO DKT8

5

OR PDIU-DS

T8
R8
PT8
PR8

NOTES:
1. Voltage levels:

T, PT = -26.3 ~ 27.8 VDC
R, PR = 0.0 VDC (GND)
(Reference to FG Ground

2. T/R wires are always required; PT/PR are additional power

wires required only for long station runs per Table 8-D.
PT/PR may be used with normal station runs also.

3. Standard Telephone circuits 1 ~ 2 require a QSTU to be

installed.

4. DKT circuits (1 ~ 4) are standard on the DK8 main PCB.
5. DKT circuits (5 ~ 6) require one optional QCDU circuit and

DKT circuit (7 ~ 8) require a second QCDU to be installed.

RELAY
CONTACTS

Advertising