12 OPTION INTERFACE UNIT

(PIOU AND PIOUS)

12.00 General

12.01 The Option Interface Unit (PIOU or PIOUS)
provides a circuit interface with peripheral options.
A maximum of one PIOU or PIOUS PCB can be
installed in the system. The PIOU and PIOUS
support the same options, except the PIOUS
does not support Zone Paging (see Paragraph
12.11).

12.02 PIOU controls, indicators, and interface
connectors are shown in Figure 5-18 and de-
scribed in Table 5-F. PIOUS information is pro-
vided in Figure 5-19 and Table 5-G.

12.03 The internal 600 ohm or 3 watt page am-
plifier of the PIOU is not supported by Strata
DK16.

12.10 PIOU and PIOUS Hardware Options

12.11 The PIOU and PIOUS support the following
STRATA DK16 hardware options:

Internal Options

Remote Maintenance Modem Unit (IMDU)

External Options

Alarm Sensor

Local Maintenance Terminal or Modem

SMDR Printer or Call Accounting Port

Remote Maintenance Port

Relay control options

Zone Page via relays (PIOU only)

NOTE:
Refer to Peripheral Equipment Installation,
Section 100-816-207, for installation of exter-
nal options.

12.12 Remote Maintenance Modem Unit (IMDU)
Installation.
Install the Remote Maintenance Mo-
dem Unit (IMDU) in accordance with the following
steps:

1)

Remove the PCB from its protective packag-
ing.