INSTALLATION-WIRING DIAGRAMS
SECTION 100-816-208
MARCH 1993

TABLE 8-B

STATION LOOP REQUIREMENTS

NOTES:
1. Use 24 AWG twisted pairs.
2. PESU circuits 3 and 4 are not used.
3. DDCB can connect only to Circuit 5 of the DK16 Base Unit or Circuit 1 of the PDKU or KCDU.
4. Two-pair, larger wire, or local telephone power supply is required to achieve maximum range,
see Table 8-D.

Device Description

Max Loop Resistance

(Including Device)

Max Distance from

KSU to Device

Number of

Wire Pairs

Standard telephones,
voice mail,
auto attendant, etc.

Electronic

4

telephone

HDSS console

Digital telephone
or
DDCB

3

DDSS console

PDIU-DI
PDIU-DI2

PDIU-DS

40 ohms

20 ohms

300 ohms

40 ohms

40 ohms

40 ohms

40 ohms

1000 ft. (303 m)

500 ft. (152 m)

1000 ft. (303 m)

1000 ft. (303 m)

1000 ft. (303 m)

1000 ft. (303 m)

2-pair. EKTs which
receive OCA calls
need 3-pair.

1-pair

1-pair

Shares digital
telephone wire-pair.

4

4

4

1-pair

4

1-pair

1

Approx. 3000 ft. (909 m)
with 150 ohm device. See
manufacturer's product
specifications for exact
resistance of device.

ADM

40 ohms

1000 ft. (303 m)

Shares digital
telephone wire-pair.

4