Toshiba Strata DK8 User Manual

Page 82

Advertising
background image

INSTALLATION-DK16 KSU & PCB
SECTION 100-816-205
MARCH 1993

5-12

AC

DC

DC POWER

–24V CIRCUIT
BREAKER
(RIGHT SIDE)

AC POWER CABLE

MOUNTING HOLE
AND SCREW

MOUNTING
SCREWS (6)

DC OUT (P9) CONNECTOR
(KPSU16 VOLTAGE TEST POINTS)

BATT

±

KRCU

PULL

LOCK

PUSH

UNLOCK

DC CABLE

RESERVE BATTERY
CONNECTOR

DC POWER
SWITCH

FG1 GREEN/YELLOW WIRE RUN
UNDERNEATH POWER SUPPLY
BEHIND STAND-OFFS

(FG) GREEN/YELLOW
WIRE WITH RING
TERMINAL THAT IS
FASTENED TO
POWER SUPPLY
FG SCREW

FG SCREW
(LEFT SIDE)

KPSU16A
POWER SUPPLY

GREEN/YELLOW WIRE
(RIGHT-HAND SIDE)

FIGURE 5-10
POWER SUPPLY (KPSU16)

4)

Plug the DC cable into the DC OUT connector.
Green/yellow wire is on right-hand side (Figure
5-10).

5)

Fasten FG green/yellow wire ring terminal and
building ground wire to the left side of the
power supply with the FG screw.

6)

Re-install K4RCU PCB (if required).

7)

Plug the AC power cable into an outlet and
turn ON the power supply switch.

8)

Refer to Paragraph 2.10 to confirm that the
power supply is working properly.

9)

Plug reserve battery cable into BATT connec-
tor of power supply (Figure 5-10).