Toshiba Strata DK8 User Manual

Page 99

Advertising
background image

5-29

INSTALLATION-DK 16 KSU & PCB

SECTION 100-816-205

MARCH 1993

TABLE 5-F

PIOU CONTROLS AND INTERFACE CONNECTORS

CONTROL/INDICATOR/

CONNECTOR

(Figure 5-18)

TYPE OF COMPONENT

DESCRIPTION

SMDR/TTY Interface
Connector J3

Dual modular connector

Interface connector for SMDR printer/
call accounting device and
maintenance terminal/modem.

10-pin connector

Three-terminal jumper plug

Interface connector for Remote
Maintenance Modem piggy-back module.

External Page/Door Lock Control Relay
MAKE or BREAK jumper plug.

IMDU Connector P1

M/B Make/Break
Jumper Plug P10

TTY Baud Rate Switch
SW2

Two-position locking push-
button switch

Selects baud rate (300 or 1200 bps) for
Remote Maintenance Modem piggy-back
module (IMDU) or external TTY jack.

Modem/TTY Switch
SW3

Enables PIOU for operation with IMDU
modem or TTY jack.

9-pin connector

Interface connector for Remote
Maintenance Modem piggy-back module.

IMDU Connector P2

3-pin connector

Interface connector for Remote
Maintenance Modem piggy-back module.

IMDU Connector P3

Three-terminal jumper plug

Night/Hold Relay MAKE or BREAK
jumper plug.

M/B Make/Break
Jumper Plug P11

Three-terminal jumper plug

Alarm sensor normally open or normally
closed jumper plug.

Alarm Sensor N.O./N.C.
Jumper Plug P12

Three-terminal jumper plug

IMDU or external modem operating
specification jumper plug.

CCITT/BELL Jumper
Plug P13

Two-position slide switch

Selects baud rate (300 or 1200 bps) for
SMDR printer or call accounting device.

SMDR Baud Rate
Switch SW1

Two-position slide switch

2) Set the SW2 baud rate switch on the front

panel to 300 or 1200, as appropriate, after the
PIOU/PIOUS has been installed in the Expan-
sion Unit (in-300 bps—out-1200 bps).

3) Set SW3 to MODEM position for IMDU opera-

tion.

4) Set the P13 jumper plug on the PIOU to the

BELL position; or, cut the W4 jumper on the
PIOUS for BELL operation.

5) Mate IMDU connectors J1, J2, and J3 with

PIOU or PIOUS connectors P1, P2, and P3

(refer to Figure 5-20).

NOTE:
PIOU or PIOUS connectors P1, P2, and P3
are positioned to allow installation of the IMDU
only in the proper position.

6) Apply firm, even pressure to IMDU to ensure

proper mating of connectors.

NOTE:
The IMDU default station intercom number is
619; and IMDU communication parameters are
7-bits, even parity, 1-stop bit.

7) Refer to Programming Procedures, Section

100-816-300, Program 77-1, and set LED 14
to ON to enable IMDU operation.