6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

37.7.4

AC’97 Controller Codec Channel Receive Holding Register

Register Name:

AC97C_CORHR

Access Type:

Read-only

• SDATA: Status Data

Data sent by the CODEC in the third AC’97 input frame slot (Slot 2).

37.7.5

AC’97 Controller Codec Channel Transmit Holding Register

Register Name:

AC97C_COTHR

Access Type:

Write-only

• READ: Read/Write command

0: Write operation to the CODEC register indexed by the CADDR address.

1: Read operation to the CODEC register indexed by the CADDR address.

This flag is sent during the second AC’97 frame slot

• CADDR: CODEC control register index

Data sent to the CODEC in the second AC’97 frame slot.

• CDATA: Command Data

Data sent to the CODEC in the third AC’97 frame slot (Slot 2).