Rainbow Electronics AT91CAP9S250A User Manual

Page 719

Advertising
background image

719

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

A bit error is set when the bit value monitored on the line is different from the bit value sent.

This flag is automatically cleared by reading CAN_SR register.

• RBSY: Receiver busy

0 = CAN receiver is not receiving a frame.

1 = CAN receiver is receiving a frame.

Receiver busy. This status bit is set by hardware while CAN receiver is acquiring or monitoring a frame (remote, data, over-
load or error frame). It is automatically reset when CAN is not receiving.

• TBSY: Transmitter busy

0 = CAN transmitter is not transmitting a frame.

1 = CAN transmitter is transmitting a frame.

Transmitter busy. This status bit is set by hardware while CAN transmitter is generating a frame (remote, data, overload or
error frame). It is automatically reset when CAN is not transmitting.

• OVLSY: Overload busy

0 = CAN transmitter is not transmitting an overload frame.

1 = CAN transmitter is transmitting a overload frame.

It is automatically reset when the bus is not transmitting an overload frame.