Reset Controller Mode Register

Register Name:

RSTC_MR

Access Type:

Read/Write

• URSTEN: User Reset Enable

0 = The detection of a low level on the pin NRST does not generate a User Reset.

1 = The detection of a low level on the pin NRST triggers a User Reset.

• URSTIEN: User Reset Interrupt Enable

0 = USRTS bit in RSTC_SR at 1 has no effect on rstc_irq.

1 = USRTS bit in RSTC_SR at 1 asserts rstc_irq if URSTEN = 0.

• ERSTL: External Reset Length

This field defines the external reset length. The external reset is asserted during a time of 2

(ERSTL+1)

Slow Clock cycles. This

allows assertion duration to be programmed between 60 µs and 2 seconds.

• KEY: Password

Should be written at value 0xA5. Writing any other value in this field aborts the write operation.

31

30

29

28

27

26

25

24

KEY

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

ERSTL

7

6

5

4

3

2

1

0

URSTIEN

URSTEN