10 waveform operating mode, 11 waveform selection – Rainbow Electronics AT91CAP9S250A User Manual

Page 655

Advertising
background image

655

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

38.5.10

Waveform Operating Mode

Waveform operating mode is entered by setting the WAVE parameter in TC_CMR (Channel
Mode Register).

In Waveform Operating Mode the TC channel generates 1 or 2 PWM signals with the same fre-
quency and independently programmable duty cycles, or generates different types of one-shot
or repetitive pulses.

In this mode, TIOA is configured as an output and TIOB is defined as an output if it is not used
as an external event (EEVT parameter in TC_CMR).

Figure 38-6

shows the configuration of the TC channel when programmed in Waveform Operat-

ing Mode.

38.5.11

Waveform Selection

Depending on the WAVSEL parameter in TC_CMR (Channel Mode Register), the behavior of
TC_CV varies.

With any selection, RA, RB and RC can all be used as compare registers.

RA Compare is used to control the TIOA output, RB Compare is used to control the TIOB output
(if correctly configured) and RC Compare is used to control TIOA and/or TIOB outputs.

Advertising