3.1

Power Distribution Board (PDB) Setup, continued

The jumpers (JP-1 and JP-2) and switches (SW-1, SW-2) are located on the Power

Distribution Board (PDB) as shown below.

Fig. 3-1, Locations of JP1, JP2 and SW1, SW2 on the Power Distribution Board (PDB)

JP 1

When configured for 120Vac Operation, the pins on

both JP1 and JP2 will be OPEN.

Two-pin jumper

JP 2

SW 1(Output)

SW 2 (Input)

Some models of the PDB’s JP1 and JP2 are two-pin jumpers, while other models have three-

pin jumpers. The voltages are configured as shown below.

120

240

When configured for 240Vac Operation, the pins on

both JP1 and JP2 will be SHORTED.

When configured for 120Vac Operation, on both JP1

and JP2 the pin marked “120” and the center pin will

be shorted as shown.

120

240 120

240

JP1

JP2

120

240

JP1

JP2

When configured for 120Vac Operation, on both JP1

and JP2 the pin marked “240” and the center pin will

be shorted as shown.

JP1

JP2

JP1

JP2

Three-pin jumper