5 configuring interface connections – Asante Technologies 40240/40480-10G User Manual

Page 180

Advertising
background image

Web – Click Port, Port Configuration or Trunk Configuration. Modify the required
interface settings, and click Apply.

Figure 8-2 Port - Port Configuration

CLI – Select the interface, and then enter the required settings.

Console(config)#interface ethernet 1/13

Console(config-if)#description RD SW#13

Console(config-if)#shutdown

.

Console(config-if)#no shutdown

Console(config-if)#no negotiation

Console(config-if)#speed-duplex 100half

.

Console(config-if)#negotiation

Console(config-if)#capabilities 100half

Console(config-if)#capabilities 100full

Console(config-if)#capabilities flowcontrol

Console(config-if)#exit

Console(config)#interface ethernet 1/21

Console(config-if)#media-type copper-forced

Console(config-if)#