Chapter 4: basic management tasks, Displaying system information, 2 basic management tasks – Asante Technologies 40240/40480-10G User Manual

Page 77

Advertising
background image

Web – Click System, System Information. Specify the system name, location, and
contact information for the system administrator, then click Apply. (This page also
includes a Telnet button that allows access to the Command Line Interface via Telnet.)

Figure 4-1 System Information

CLI – Specify the hostname, location and contact information.

Console(config)#hostname R&D 5

23-1

Console(config)#snmp-server location WC 9

24-4

Console(config)#snmp-server contact Ted

24-4

Console(config)#exit

Console#show system

23-7

System Description: 24/48 port 10/100/1000 Stackable Managed Switch with

2 X 10G

uplinks

System OID String: 1.3.6.1.4.1.259.8.1.9

System Information

System Up Time:

0 days, 1 hours, 28 minutes, and 0.51 seconds

System Name:

R&D 5

System Location:

WC 9

System Contact:

Ted

MAC Address (Unit1):

00-20-1A-DF-9C-A0

MAC Address (Unit2):

00-20-1A-DF-9E-C0

Web Server:

Enabled

Web Server Port:

80

Web Secure Server:

Enabled

Web Secure Server Port: 443

Telnet Server:

Enable

Telnet Server Port:

23

Authentication Login:

Local RADIUS None

Jumbo Frame:

Disabled

Jumbo Frame Size:

1522

POST Result:

DUMMY Test 1 ................. PASS

DRAM Test .................... PASS

Timer Test ................... PASS

PCI Device 1 Test ............ PASS

I2C Bus Initialization ....... PASS

Fan Speed Test ............... PASS

Done All Pass.

Console#

4-2

Basic Management Tasks

4

Advertising