Show start button leds, Show cycle counter led – Gilderfluke&Co KP-300 Smart Brick Control Panel User Manual

Page 13

Advertising
background image

the safety inputs can be logged by either pressing the

Log Belts Button

or

activating the

Remote Log Belts Input

by pressing

Remote Log Belts But-

ton(s)

attached to it. If you want to automatically log belts from the motion

profile, just set the

Remote Log Belts Input

for Internal Power and attach the

two wires for this input together so it is always active. Whenever the

Show

Pause Reset Input

is programmed active, the inputs that are set to be

logged will automatically be logged.

Input logging actually takes place at the instant that the

Log Belts Button

,

Log Belts Remote Input

, or

Show Pause Reset Input

are released.

E) Show Start Button LEDs

(One green LED for each Show Start Button)

!

(Eight LEDs total)

These LEDs are controlled directly by the motion control profile stored in

the Smart Brick System. This allows the LEDs to be programmed on, off or
flashing as desired at any point in time. They are programmed to indicate
which shows are available to the operator, or to indicate which show is al-
ready running. We typically program them in a chase pattern, lighting only
the valid show selections. Once a show has started, we typically program all
but the selected

Show Start Button LEDs

off, and flash the selected show

LED a few times before turning it on through the rest of the show. If any
other show selection is valid while another show is running, we then flash it
discretely throughout the show that is running.

Whenever a

Show Start Button LED

is programed to indicate that a

Show

Start Button

is valid, it is also necessary to actually enable the correspond-

ing

Show Start Button Enable Input

output from the Smart Brick System to

make the

Show Start Buttons

active. If this is not done, then the

Show Start

Buttons

will remain inactive.

F) Show Cycle Counter LED

(One green LED)

This LED lights to show that the show cycle counter has been com-

manded to advance by the motion control profile stored in the Smart Brick
System. The count on the LCD counter will advance by one if the Kp-300 is
not currently in any type of E-Stop condition and the HPU is running, as indi-
cated by 24 vdc being received on the

HPU Running Input

.

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485

Kp-300 Manual / September 4, 2012 4:29 PM / page 13 of 75

Advertising