J2 Inputs & Outputs to the Kp-300

(M

ALE

DB-25

C

ONNECTOR

)

This connector contains the remaining five Error Inputs, as well as the

HPU Run

Output

signal that turns the HPU on and off and the

Remote Log Belts Input

.

!

J2:!1 (-), 14 (+):!!

HPU Stopped Input

to Kp-300 (24 vdc from HPU)

!

J2:!2 (-), 15 (+):!!

HPU Running Input

to Kp-300 (24 vdc from HPU)

!

J2:!3 (-), 16 (+):!!

Blocking Valve Output

(24 vdc, 150ma output)

!

J2:!4 (-), 17 (+):!!

HPU Run Output

(24 vdc, 150ma output)

!

J2:!5 (-), 18 (+):!!

Remote Belt Log Button

(24 vdc optoisolated input)

!

J2:!6 (-), 19 (+):!!

Error Input to Kp-300 #15

!

J2:!7 (-), 20 (+):!!

Error Input to Kp-300 #14

!

J2:!8 (-), 21 (+):!!

Error Input to Kp-300 #13

!

J2:!9 (-), 22 (+):!!

Error Input to Kp-300 #12

!

J2:!10 (-), 23 (+):!

Error Input to Kp-300 #11

!

J2:!11, 12, 13:!!

Ground

!

J2:! 24, 25:! !

+ 24 vdc

1) HPU Stopped Input to Kp-300

This input is used to light the

HPU Stopped LED

. This LED shows that the Hy-

draulic Power Unit (HPU) is not running. Unlike the

HPU Running Input

, this input

is not used for any other purpose than lighting the

HPU Stopped LED

.

This input should be fed 24 vdc from the HPU controller whenever the HPU is

not running.

To help keep shows from being started when the HPU has been started by its

local Hand/Off/Auto switch, the

HPU Stopped Input

and

HPU Running Input

sig-

nals are often routed through the ʻAutoʼ position on the switch. If the switch isnʼt in
the ʻAutoʼ position, the

HPU Stopped

and

HPU Running LEDs

wonʼt light and the

Blocking Valve output

wonʼt be enabled.

If there is no HPU in your application, or there is no ʻstoppedʼ output from your

HPU, you can turn on

DipSwitch #1

. The

ʻHPU Stoppedʼ LED

will then light when-

ever the Kp-300 thinks that the HPU is not running.

2) HPU Running Input to Kp-300

This input is used to light the

HPU Running LED

and qualify the

Show Cycle

Counter

and

Blocking Valve Output

. This signal normally comes from the HPU.

The

HPU Running LED

lights to show that the Hydraulic Power Unit (HPU) is run-

ning.