The 24 vdc supply and ground lines can be used to power sensors or other de-

vices. They are PTC fused for 1.1 amp of current.

4) Thirty-two Optoisolated Inputs To The Kp-300 Expansion

(40

P

OSITION

J6

S

HROUDED

M

ALE

H

EADER

)

This connector is used for thirty-two more optically isolated Inputs to the Kp-

300 Expansion. You must provide power to this input on the ʻ+24 vdc Supplyʼ pins,
and ground the inputs to the same power supply to make them active.

!

Wire #!Color! Bit #!

Description

! 1! Brown!

!

Ground

! 2!

Red! Bit 7!

Error Input #8 To Kp-300 Expansion

! 3! Orange!Bit 6!

Error Input #7 To Kp-300 Expansion

! 4! Yellow! Bit 5!

Error Input #6 To Kp-300 Expansion

! 5! Green! Bit 4!

Error Input #5 To Kp-300 Expansion

! 6!

Blue! Bit 3!

Error Input #4 To Kp-300 Expansion

! 7!

Violet! Bit 2!

Error Input #3 To Kp-300 Expansion

! 8!

Gray! Bit 1!

Error Input #2 To Kp-300 Expansion

! 9!

White! Bit 0!

Error Input #1 To Kp-300 Expansion

!10! Black!

!

+ 24 Vdc Supply

!11! Brown!

!

Ground

!12!

Red! Bit 7!

Error Input #16 To Kp-300 Expansion

!13! Orange!Bit 6!

Error Input #15 To Kp-300 Expansion

!14! Yellow! Bit 5!

Error Input #14 To Kp-300 Expansion

!15! Green! Bit 4!

Error Input #13 To Kp-300 Expansion

!16!

Blue! Bit 3!

Error Input #12 To Kp-300 Expansion

!17! Violet! Bit 2!

Error Input #11 To Kp-300 Expansion

!18!

Gray! Bit 1!

Error Input #10 To Kp-300 Expansion

!19! White! Bit 0!

Error Input #9 To Kp-300 Expansion

!20! Black!

!

+ 24 Vdc Supply

!21! Brown!

!

Ground

!22!

Red! Bit 7!

Error Input #24 To Kp-300 Expansion

!23! Orange!Bit 6!

Error Input #23 To Kp-300 Expansion

!24! Yellow! Bit 5!

Error Input #22 To Kp-300 Expansion

!25! Green! Bit 4!

Error Input #21 To Kp-300 Expansion

!26!

Blue! Bit 3!

Error Input #20 To Kp-300 Expansion

!27! Violet! Bit 2!

Error Input #19 To Kp-300 Expansion

!28!

Gray! Bit 1!

Error Input #18 To Kp-300 Expansion

!29! White! Bit 0!

Error Input #17 To Kp-300 Expansion

!30! Black!

!

+ 24 Vdc Supply

!31! Brown!

!

Ground

!32!

Red! Bit 7!

Error Input #32 To Kp-300 Expansion

!33! Orange!Bit 6!

Error Input #31 To Kp-300 Expansion

!34! Yellow! Bit 5!

Error Input #30 To Kp-300 Expansion

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485