configured to pause the currently running show on a closure on this input

5

.

When a show is 'continued', the signal is dropped on the

Green ʻPauseʼ

Output

to the Smart Brick Brain. This input must be configured to continue

the currently running show on an opening on this input.

Once a show has been paused, the only two ways to 'continue' a show

are to:

a) Send an active signal from the Smart Brick System to the Kp-

300ʼs

Show Pause Reset Input

.

b) Once the condition that caused the Show Pause has been re-

moved, the operator can press the

Show Continue button

.

U) DMX-512 Receive LED (v3.0+ Only)

(One red LED, Located on back of Kp-300)

To support the DMX-512 input, the v3.0+ Kp-300 adds an LED that

flashes on each update via the DMX-512.

The Kp-300 requires DMX-512 that includes GilderChecksums.

If receiving DMX-512 without valid checksums, the

DMX-512 Receive

LED

on the back of the Kp-300 will not flash and only the

Show Start Button

LEDs

will follow the incoming the DMX-512. The signals like the

Show Start

Button Enable Input

s, blocking valve enable, and automatic

HPU start

/

stop

will not work if the GilderChecksums are invalid.

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485

Kp-300 Manual / September 4, 2012 4:29 PM / page 21 of 75

5

In some applications, you may want to call up a different show using this input, instead of pausing the current show.