Gilderfluke&Co KP-300 Smart Brick Control Panel User Manual

Page 46

Advertising
background image

Program a

Remote HPU Start Input

into the show data. When

the HPU is started as part of the motion profile, there will usually
be a time just after it is started where any HPU pressure sensors
inputs will need to be bypassed. In this case, you can see ʻBy-
pass 2ʼ being used for this at the start of the show. The

Bypass

Buss

needs to be active for the time it takes for the HPU to build

up pressure. If the pressure sensor doesnʼt come up during the
time allotted, the Kp-300 will automatically trigger an error condi-
tion.

e) (optional)If you are using the

Remote HPU Stop Input

features: If

the HPU is to be turned off at the end of the show, then the same

Bypass Buss

which is being used for turning on the HPU will

need to be programmed active along with a pulse on the

Remote

HPU Stop Input

. This allows the HPU to be stopped without trig-

gering an error condition. If configured to trigger an E-Stop, the

Bypass Buss

may also need to be programmed active during the

E-Stop and Load/Unload shows so that the HPUʼs low pressure
wonʼt trigger an error during these shows when the HPU is off.

f) Turn off the

Show Start Button LEDs

. We typically program them

in a chase pattern during the E-Stop and Load/Unload shows,
lighting only the valid show selections. Once a show has started,
we typically program all but the selected

Show Start Button

LEDs

off, and flash the selected show LED a few times before

turning it on through the rest of the show. If any other show se-
lection is valid while another show is running, we then flash it
discretely throughout the show that is running. In this case, no
other shows can be started during this ʻMainʼ show.

#

Whenever a

Show Start Button LED

is programed to indicate

that a show select

Show Start Buttons

is valid, it is also neces-

sary to actually enable and/or disable the corresponding

Show

Start Button Enable Input

.

g) Enable/Disable the

Show Start Button Enable Input

for whatever

show(s) you want the operator to be able to call up next. Typi-
cally there arenʼt any during the Main shows. If there is one, then
it is probably a show that has been written to ʻparkʼ the motion
base without having to E-Stop the system.

h) Just before the ride comes to an end, pulse the ʻ

Cycle Counter

ʼ

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485