sors, over temperature warnings, and other sensors on the HPU are often wired to
these inputs.

Each of these error inputs are optoisolated and can be configured to be run

from the same 24 vdc supply as the Kp-300, or from an external source of 24 vdc.
All of these inputs ʻfail safeʼ. This is to say that they are triggered by an opening,
and would also be triggered if the wires running to them broke open. Each input
can be configured to cause the following on opening:

a) E-Stop

b) Pause a running show

c) Force off the HPU as long as it is opened.

Other jumpers allow these inputs to be logged as temporarily inactive, or by-

passed temporarily from the motion control profile stored on the Smart Brick Sys-
tem.