Kp-300 Expansion

The Kp-300 Expansion is a 3.5” (2U), 19” rack mounted panel that can be used to

add additional inputs and outputs to those found on the standard Kp-300:

1) Eight medium current (¼ J6 pinout)

2) Six High current optoisolated outputs (Six 2 position screw terminals)

3) Sixteen uncommitted optoisolated inputs (two DB-25 females)

4) Thirty-two optoisolated inputs (one J6 male header)

5) Sixteen uncommitted Red indicator LEDs

6) Sixteen uncommitted Yellow indicator LEDs

Unlike the Kp-300, the Kp-300 Expansion must be factory configured for your appli-

cation. The Kp-300 Expansion has a large CPLD on it, so it is possible to configure it for
some very complex logic. It can be configured to control ramps and doors, provide the
logic for occupancy sensors and seat belts, or just about anything else you can think of.

1) Eight Medium Current Outputs

(10

P

OSITION

¼

J6

S

HROUDED

M

ALE

H

EADER

)

These eight outputs can each sink 150 ma of current at 24 vdc, or a total of 1.1

amps on all eight outputs. Whatever you are controlling should be connected be-
tween the +24 vdc Supply Output on pin #10, and the output pin (#2 through #9).

!

Wire #!Color! Bit #!

Description

! 1! Brown!

!

Ground

! 2!

Red! Bit 7!

Output #8 From Kp-300 Expansion

! 3! Orange!Bit 6!

Output #7 From Kp-300 Expansion

! 4! Yellow! Bit 5!

Output #6 From Kp-300 Expansion

! 5! Green! Bit 4!

Output #5 From Kp-300 Expansion

! 6!

Blue! Bit 3!

Output #4 From Kp-300 Expansion

! 7!

Violet! Bit 2!

Output #3 From Kp-300 Expansion

! 8!

Gray! Bit 1!

Output #2 From Kp-300 Expansion

! 9!

White! Bit 0!

Output #1 From Kp-300 Expansion

!10! Black!

!

+ 24 Vdc Supply

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485