G) 24 vdc Power Input to the Kp-300 (v3.0+ Only)

(T

WO

P

OSITION

S

CREW

T

ERMINAL

)

Connect the regulated 24 vdc used to power the Kp-300 to these two terminals.

The Kp-300 usually shares power with the Smart Brick System that runs it.

H) Kp-300 Expansion for the Kp-300 (v3.0+ Only)

(16

P

OSITION

R

IBBON

C

ABLE

C

ONNECTOR

)

The Kp-300 can be used to add up to fifty-six additional optically isolated in-

puts, and up to fourteen additional outputs. It can be factory programmed to con-
trol entry ramps and bridges for motion bases, addition seat belt and occupancy
sensors.

I)

ʻAlarmʼ Output (v3.0+ Only)

(T

WO

P

OSITION

S

CREW

T

ERMINAL

)

This output provides a 24 vdc signal when

DipSwitch #6

,

DipSwitch #7

or

DipSwitch #8

are switched on to give an alarm on the activation of the

E-stop

Buss

(

E-Stop Buss LED

is lit),

HPU-Stop Buss

(

HPU-Stop LED

is lit), or

Pause

Buss

(

Show Pause Buss LED

is lit). This can be used to drive an audio annuncia-

tor like a Sonalert module directly (up to 24 vdc at 150 ma continuous). Heavier
loads (like an alarm bell) will require a solid state relay between this output and
the bell.