trigger an E-Stop, they will need to be bypassed during the E-
Stop and Load Unload shows. This is because although you
want these inputs to trigger an error while the motion base is in
motion, you donʼt want this to trigger an E-Stop when someone
opens the doors for the passengers to be loaded and unloaded.

c) Electric Motion Bases and other Installations that donʼt use

the Kp-300

Blocking Valve Output

: If you donʼt want to allow

shows to be run if there is an E-Stop condition present, you can
configure one of the two

bypass busses

to momentarily (for just

one frame) bypass all the possible error inputs at the very start
of all shows

12

. At the end of the

bypass buss

pulse, any error

conditions that remain will trigger the E-Stop to keep even the
video and audio from running. This technique should be used in
applications that donʼt use the

Blocking Valve Output

. Typical of

these are most electric motion base installations.

If you are using the Seat Belt Logging features of the Kp-300, be sure you

donʼt configure the Kp-300 to bypass any inputs that are to be logged during
the time during which they need to be logged. Bypassing an input will con-
vince the Kp-300 that the inputs are in the ʻsafeʼ position, and so they will not
be logged as ʻunoccupiedʼ.

The Show Pause functions are usually disabled during the E-Stop and

Load/Unload shows by the

Show Pause Reset Input

from the Smart Brick

System. Inputs that trigger a Show Pause are usually not needed during the
E-Stop and Load/Unload shows anyway, so there is no need to bypass them
separately during these shows.

H) HPU-Stop Buss

(One jumper for each safety input)

Any or all of the fifteen Safety Inputs can be set to force the HPU off, re-

gardless of the E-Stop and Show Pause busses.

not used

Pump Stop

When the jumper for an input is set to the HPU Stop position, the HPU

cannot be started until this error condition is reset. This jumper is normally
used only on inputs that are also configured to trigger an E-Stop.

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485

Kp-300 Manual / September 4, 2012 4:29 PM / page 32 of 75

12

This technique is flexible enough that you can even leave it out of any maintenance shows that you want to be able to run without

motion.