J1 Inputs to the Kp-300

(F

EMALE

DB-25

C

ONNECTOR

)

This connector is used for the first ten Error Inputs to the Kp-300.

!

J1:!1 (-), 14 (+):!!

Error Input to Kp-300 #1

!

J1:!2 (-), 15 (+):!!

Error Input to Kp-300 #2

!

J1:!3 (-), 16 (+):!!

Error Input to Kp-300 #3

!

J1:!4 (-), 17 (+):!!

Error Input to Kp-300 #4

!

J1:!5 (-), 18 (+):!!

Error Input to Kp-300 #5

!

J1:!6 (-), 19 (+):!!

Error Input to Kp-300 #6

!

J1:!7 (-), 20 (+):!!

Error Input to Kp-300 #7

!

J1:!8 (-), 21 (+):!!

Error Input to Kp-300 #8

!

J1:!9 (-), 22 (+):!!

Error Input to Kp-300 #9

!

J1:!10 (-), 23 (+):!

Error Input to Kp-300 #10

!

J1:!11, 12, 13:!!

Ground

!

J1:! 24, 25:! !

+ 24 vdc

Each of the error inputs are optoisolated and can be configured to be run from

the same 24 vdc supply as the Kp-300, or from an external source of 24 vdc. All of
these inputs ʻfail safeʼ. This is to say that they are triggered by an opening, and
would also be triggered if the wires running to them broke open. Each input can be
configured to cause the following on opening:

a) E-Stop

b) Pause a running show

c) Force off the HPU as long as it is opened.

Other jumpers allow these inputs to be logged as temporarily inactive, or by-

passed temporarily from the motion control profile stored on the Smart Brick Sys-
tem.

The 24 vdc supply and ground lines can be used to power sensors or other de-

vices. They are wired in parallel with the 24 vdc connector on J2. Between them,
they are PTC fused for 1 amp of current.