Dmx-512 address selection on the kp-300 (v3.0+) – Gilderfluke&Co KP-300 Smart Brick Control Panel User Manual

Page 37

Advertising
background image

DMX-512 Address Selection on the Kp-300 (v3.0+)

(T

WO

H

EXADECIMAL

D

IP

S

WITCHES

)

To support the DMX-512 input, the v3.0+ Kp-300 adds a two position rotary

DipSwitch which is used to set the DMX-512 address

The DMX-512 addressing is zero-based, HEXadecimal numbering.

Valid addresses between 00h and FFh. We typically set the Kp-300 to an address of

00h thru 02h, and then address the motion base legs and outputs for starting the videos,
lights and ʻ4dʼ effects starting at 03h.

The Kp-300 requires DMX-512 that includes GilderChecksums. If receiving DMX-512

without valid checksums, the

DMX-512 Receive LED

on the back of the Kp-300 will not

flash and only the

Show Start Button LEDs

will follow the incoming the DMX-512. The

signals like the

Show Start Button Enable Input

s, blocking valve enable, and automatic

HPU start

/

stop

will not work when the GilderChecksums are invalid.

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485

Kp-300 Manual / September 4, 2012 4:29 PM / page 37 of 75

Advertising