disable the Kp-300 Show Pause functions. This is normally programmed ac-
tive only during the E-Stop and Load/Unload shows.

Seat belts can be logged at any time that the

Show Pause Reset Input

from the Smart Brick System is active. When this input is active, the safety
inputs can be logged by either pressing the

Log Belts button

or activating the

Remote Log Belts Input

by pressing

Remote Log Belts Button(s)

attached to

it. If you want to automatically log belts from the motion profile, just set the

Remote Log Belts Input

for Internal Power and attach the two wires for this

input together so it is always active. Whenever the

Show Pause Reset Input

is programmed active, the inputs that are set to be logged will automatically
be logged.

Input logging actually takes place at the instant that the

Log Belts Button

,

Remote Log Belts Input

, or

Show Pause Reset Input

are released. The LED

next to the

Log Belts Button

will light whenever the seat belts are being

logged.

Q) HPU Running LED

(One green LED)

This LED lights to show that the Hydraulic Power Unit (HPU) is running.

This LED is turned on only when a 24 vdc signal is applied to the

HPU Run-

ning Input

. This signal normally comes from the HPU. If there is no HPU in

the system, this input can be permanently attached to a 24 vdc or the

HPU

Run Output

.

Unless this signal is received by the Kp-300, the

Blocking Valve Output

will never turn on and the Show Cycle Counter will not advance.

To help keep shows from being run when the HPU has been started by its

local Hand/Off/Auto switch, the

HPU Stopped Input

and

HPU Running Input

signals are often routed through the ʻAutoʼ position on the switch. If the
switch isnʼt in the ʻAutoʼ position, the

HPU Stopped LED

and

HPU Running

LED

wonʼt light and the Blocking valve wonʼt be enabled.

R) HPU Stopped LED

(One red LED)

This LED lights to show that the Hydraulic Power Unit (HPU) is not run-

ning. This LED is turned on only when a 24 vdc signal is applied to the