Moog E-Stop command requires that the PC under the Moog mo-
tion base be rebooted before the motion base will move again. This
is a little too drastic for our tastes. The Moog Park will just move the
motion base home if it is engaged. The Moog Reset will reset any
minor error conditions in the PC under the motion base. If the Moog
motion base isnʼt in either of these conditions, these commands
wonʼt do anything.

C) Load/Unload Show

This is the show that all the main shows jump to at their ends. It loops to

flash the

Show Start button Enable LEDs

until the next show is selected and

started. You can see that this show is identical to the E-Stop show, except
the ʻE-Stop Showʼ output which was ʻonʼ throughout the E-Stop Shows, is off
through the Load/Unload show.

The Load/Unload show must:

a) The motion base is programmed with all axis at the parked posi-

tions. This can be seen in the upper, analog data pane. All the ana-
log channels are down along the bottom ʻ0%ʼ line.

b) Disable the

Blocking Valve Output

to the Kp-300. This will park a

hydraulic Motion base (the hardware on the Kp-300 will have actu-
ally turned off the output prior to this). The ʻBlocking Valveʼ output is
ʻoffʼ through all four seconds of the show.

c) Turn on the ʻ

E-Stop Show Running

ʼ Output to the Kp-300. If you

donʼt do this, you wonʼt be able to restart the HPU to get yourself
out of the E-Stop event. The ʻE-Stop Showʼ output is ʻonʼ through
the show.

d) Turn on any of the

Bypass Outputs

that are needed to recover from

the E-Stop event. In this application, the ʻBypass 1ʼ is used during
the E-Stop and Load/Unload shows to keep the doors being
opened and people walking in and out from triggering additional E-
Stops. ʻBypass 2ʼ is unused in this application.

e) Flash the

Show Start Button LED(s)

for whatever show you want

the operator to be able to call up next. This is so the operator knows
which show options are available. We typically program them in a
chase pattern during the E-Stop and Load/Unload shows, lighting

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485

Kp-300 Manual / September 4, 2012 4:29 PM / page 41 of 75

Advertising