only the valid show selections. The eight ʻShow Pilotʼ outputs are
shown doing a simple circular chase pattern.

f) Whenever a

Show Start Button LED

is programed to indicate that a

Show Start Buttons

is valid, it is also necessary to actually enable

the corresponding

Show Start Button Enable Input

from the Smart

Brick System to make the

Show Start Buttons

active. If this is not

done, then the

Show Start Buttons

will remain inactive. All eight

ʻShow Enablesʼ are ʻonʼ through the show, so all eight Show Start

Buttons are enabled.

g) The ʻ

Show Pause Reset

ʼ is ʻonʼ through the show to reset any po-

tential ʻpausesʼ.

h) The

ʻBypass 2ʼ

,

ʻHPU Startʼ

, ʻ

HPU Stopʼ

and

ʻCycle Counterʼ

are not

used during the Load/Unload show.

i) (optional) Open any cabin doors as needed. Sometimes cabin

doors are manually operated, sometimes they are automated. If

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485

Kp-300 Manual / September 4, 2012 4:29 PM / page 42 of 75