ʻPauseʼ. Typically this is done during the E-Stop and Load/Unload shows to
prevent these shows from being paused.

F) Bypass Buss One

G) Bypass Buss Two

(One jumper for each safety input)

The fifteen Safety Inputs can be temporarily disabled from causing a

Show Pause or E-Stop from the motion profile programmed into the Smart
Brick System.

Bypass #1

Bypass #2

To keep an input from triggering a Show Pause/E-Stop when

Bypass

Buss #1

is active, move the jumper to the middle and left two pins. To keep

an input from triggering a Show Pause/E-Stop when

Bypass Buss #2

is ac-

tive, move the jumper to the middle and right two pins. If this feature is not to
be used on an input, remove the jumper altogether.

Typical examples of the use of the

bypass buss

are:

a) HPU Startup/Shutdown: If the HPU is started and stopped as

part of the motion profile, there will usually be a time just after it
is started and a time after it is stopped where any HPU pressure
sensors inputs will need to be bypassed. Do this by program-
ming the

Bypass Buss

you are using and

Remote HPU Start In-

put

to be active at the beginning of the show. The

Bypass Buss

needs to be active for the time it takes for the HPU to build up
pressure. If the pressure doesnʼt come up during the time allot-
ted, the Kp-300 will automatically trigger an error condition (ei-
ther E-Stop or Show Pause, as configured).

#

If the HPU is to be turned off at the end of the show, then the

Bypass Buss

which is being used would be programmed active

along with a pulse on the

Remote HPU Stop Input

. This allows

the HPU to be stopped without triggering an error condition. If
configured to trigger an E-Stop, the

Bypass Buss

may also need

to be programmed active during the E-Stop and Load/Unload
shows so that the HPUʼs low pressure wonʼt trigger an error dur-
ing these shows when the HPU is off.

b) Door Sensors: If the door or floor mat sensors inputs are set to

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485

Kp-300 Manual / September 4, 2012 4:29 PM / page 31 of 75