E-stop show running led, Remote hpu start led, Remote hpu stop led – Gilderfluke&Co KP-300 Smart Brick Control Panel User Manual

Page 18: Show pause reset led

Advertising
background image

vince the Kp-300 that the inputs are in the ʻsafeʼ position, and so they will not
be logged as ʻunoccupiedʼ.

The Show Pause functions are usually disabled during the E-Stop and

Load/Unload shows by the

Show Pause Reset Input

from the Smart Brick

System. Inputs that trigger a Show Pause are never needed during the E-
Stop and Load/Unload shows anyway, so there is no need to bypass them
separately during these shows.

M) E-Stop Show Running LED

One green LED

This LED lights to show that the motion control profile is running the E-

Stop Show. The

E-Stop Show Running

output is normally only programmed

active during the E-Stop Show, and is used reset one of the Kp-300ʼs on-
board latches to allow the HPU to be started and the E-Stop conditions to be
cleared.

N) Remote HPU Start LED

O) Remote HPU Stop LED

(Two green LEDs)

These LEDs light to show that the motion control profile on the Smart

Brick System has had the commands to start or stop the HPU embedded in
it. This is an optional feature. If you donʼt want the HPU to be started and
stopped automatically, just donʼt use them.

These outputs parallel the

HPU Start Button

and

HPU Stop Button

that

are on the front of the Kp-300. If the HPU is being forced off by a

HPU Stop

Buss

error, the

Remote HPU Start Input

can NOT override the error.

Any of the ʻstopʼ inputs take precedence over any of the ʻstartʼ inputs. You

can use an active

Remote HPU Stop Input

in the motion profile stored on the

Smart Brick System to keep the operator or

Remote HPU Start Input

from

starting the HPU.

P) Show Pause Reset LED

(One green LED)

This LED lights to show that the motion control profile on the Smart Brick

System has the

Show Pause Reset Input

command programmed to reset or

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485

Kp-300 Manual / September 4, 2012 4:29 PM / page 18 of 75

Advertising