LEESON Micro Series Compact Inverters User Manual
Page 16

14
230 VOLT MICRO SERIES RATINGS
MODEL
INPUT OUTPUT
(200/240 Vac, 50-60 Hz)
(0-200/230 Vac)
FOR MOTORS
NOMINAL
NOMINAL
CATALOG
RATED
INPUT
CURRENT
POWER
CURRENT POWER
NUMBER
HP
kW
PHASE
(AMPS)
(KVA)
(AMPS)
(KVA)
174914
174935*
.50
0 .37
3
3 .1/2 .7
1 .1
2 .5/2 .2
0 .88
174527**
174915
174936*
1
0 .75
3
5 .5/4 .8
2 .0
4 .6/4 .0
1 .6
174528**
174916
174482*
1 .5
1 .1
3
7 .1/6 .2
2 .6
6 .0/5 .2
2 .1
174529**
174917
174937*
2
1 .5
3
9 .3/8 .1
3 .4
7 .8/6 .8
2 .7
174530**
174918
174938*
3
2 .2
3
13 .0/11 .3
4 .7
11 .0/9 .6
3 .8
174531**
174919
174730*
5
3 .7
3
20 .0/17 .7
7 .4
17 .5/15 .2
6 .1
174732**
174545
174734*
7 .5
5 .5
3
30/26
10 .6
25/22
8 .8
174735**
174551
174737*
10
7 .5
3
37/32
13 .2
32/28
11 .2
174738**
174557
174740*
15
11
3
55/48
19 .8
48/42
16 .7
174741**
174560
20 15
3 70/61 25 .3 62/54 21 .5
174743*
174569
25 18 .5 3 89/77 32 .0 78/68 27 .1
174595*
174571
30 22
3 104/90 37 .6 92/80 31 .9
174596*
174576
40
30
3
119/99
41 .0
120/104
41 .4
174578
60
45
3
174/145
60 .5
177/154
61 .3
NOTE See Section 8 .0 for recommended fuse type .
* = NEMA 4/12 or 12 ENCLOSURE
** = NEMA 4X ENCLOSURE
OTHERS ARE NEMA 1 ENCLOSURE