17.0 PARAMETER MENU

NOTE 1: REFER TO SECTION 18 .0 - DESCRIPTION OF PARAMETERS .

NOTE 2: MAX LIMIT IS 650 Hz ON UNITS WITH HIGH FREQUENCY SOFTWARE.

NOTE 3: IF LINE VOLTS IS SET TO “LOW” (OR SET TO “AUTO” AND THE INPUT

VOLTAGE IS LOW), RANGE IS 25 - 150%.

PARAMETER MENU

PARAM.

PARAMETER

RANGE OF

FACTORY

NUMBER

NAME

ADJUSTMENT

DEFAULT

0

LINE VOLTS

HIGH, LOW, AUTO

AUTO

1

SPEED #1

MIN FRQ - MAX FRQ

20.00 Hz

2

SPEED #2

MIN FRQ - MAX FRQ

20.00 Hz

3

SPEED #3

MIN FRQ - MAX FRQ

20.00 Hz

4

SPEED #4

MIN FRQ - MAX FRQ

20.00 Hz

5

SKIP #1

.00 Hz - MAX FRQ

0.00 Hz

6

SKIP #2

.00 Hz - MAX FRQ

0.00 Hz

7

BAND WID

.00 - 10.00 Hz

1.00 Hz

8

ACCEL

NOTE 1

30 .0 SEC

9

DECEL

NOTE 1

30 .0 SEC

10

MIN FRQ

.00 - MAX FRQ

0.50 Hz

11

MAX FRQ

MIN FRQ - 120.0 HZ (NOTE 2)

60.00 Hz

12

DC BRAKE

NOTE 1

0 .0 VDC

13

DC TIME

.0 - 999 .9 SEC

0 .0 SEC

14

DYN BRAKE

OFF, ON

OFF

16

CURRENT

25 - 180% (NOTE 3)

180%

17

MOTOR OL

25 - 100%

100%

18

BASE

20.00 - 360.0 Hz (NOTE 2)

60.00 Hz

19

FX BOOST

.0 - 30 .0%

NOTE 1

20

AC BOOST

.0 - 20 .0%

0 .0%

21

SLIP COMP

.0 - 5 .0%

0 .0%