LEESON Micro Series Compact Inverters User Manual

Page 52

Advertising
background image

50

PARAMETER MENU

PARAM.

PARAMETER

RANGE OF

FACTORY

NUMBER

NAME

ADJUSTMENT

DEFAULT

65

PROGRAM

MAINTAIN, RESET 60,

RESET 50 (NOTE 4)

RESET 60

66

HISTORY

MAINTAIN, CLEAR

MAINTAIN

70

PID MODE

OFF, NORMAL, REVERSE

OFF

74

PID FB

TB-5A, TB-5B

TB-5A

75

FB @ MIN

-32768 to 32767

0 .0 %

76

FB @ MAX

-32768 to 32767

100 .00 %

77

P GAIN

0 .0 - 999 .9 %

5 .0 %

78

I GAIN

0 .0 - 10 .0 SEC

0 .0 SEC

79

D GAIN

0 .0 - 10 .0 SEC

0 .0 SEC

80

PID ACC

0 .0 - 100 .0 SEC

30 .0 SEC

81

MIN ALRM

FB @ MIN - FB @ MAX

0 .0 %

82

MAX ALRM

FB @ MIN - FB @ MAX

0 .0 %

98

LANGUAGE

ENGLISH

99

FAULT HISTORY

(VIEW - ONLY)

(N/A)

NOTE 4: “RST HIGH” WILL APPEAR ON UNITS SET UP FOR HIGH FREQUENCY.

NOTE!

If you are working with Software M108313 or earlier (see Parameter 63), parameters 69 and 70 are

shown here as parameters 98 and 99.