LEESON Micro Series Compact Inverters User Manual
Page 51

49
PARAMETER MENU
PARAM.
PARAMETER
RANGE OF
FACTORY
NUMBER
NAME
ADJUSTMENT
DEFAULT
43
@TB10A
0.00 - 360.0 HZ (NOTE 2)
60.00 Hz
44
TB10B OUT
NONE, 0-10V, 2-10V
NONE
45
@TB10B
10 - 200%
125%
47
TB13A
NONE, 0-10VDC, 4-20MA,
NONE
SPEED #1, LOC SEL,
DEC FREQ
48
TB13B
NONE, 0-10VDC, 4-20MA,
NONE
SPEED #2, INC FREQ,
JOG FWD, JOG REV
49
TB13C
NONE, 0-10VDC, 4-20MA,
NONE
SPEED #3, LOC SEL,
RUN REV, STRT REV
50
TB13D
EXT FAULT, EXT
EXT FAULT
/FAULT, EXT CLEAR
NONE, RUN, FAULT, /FAULT,
LOCK, @ SPEED, ABOVE #3,
I LIMIT, AUT/MAN, FLWR PR,
52
TB14 OUT
MIN/MAX ALARM,
53
TB15 OUT
INV MIN/MAX A,
NONE
54
RELAY
MIN ALARM, INV MIN ALARM,
MAX ALARM, INV MAX ALARM,
REVERSE, SLEEP, SPD = 0HZ
55
TB5B
LOSS FAULT, SP#4, NONE
FAULT
57
SERIAL
DISABLED, W/TIMER, W/O TIMR
DISABLE
58
ADDRESS
1 - 247
30
61
PASSWORD
0000 - 9999
0019
63
SOFTWARE
(VIEW - ONLY)
(N/A)
64
MONITOR
OFF, ON
ON
NOTE 2: MAX LIMIT IS 650 Hz ON UNITS WITH HIGH FREQUENCY SOFTWARE.