575 VOLT MICRO SERIES RATINGS

MODEL

INPUT OUTPUT

(480/590 Vac, 50-60 Hz)

(0-460/575 Vac)

FOR MOTORS

NOMINAL

NOMINAL

CATALOG

RATED

INPUT

CURRENT

POWER

CURRENT POWER

NUMBER

HP

kW

PHASE

(AMPS)

(KVA)

(AMPS)

(KVA)

174925

174943*

1

0 .75

3

1 .9 / 1 .9

1 .9

1 .6 / 1 .6

1 .6

174536**

174926

174944*

2

1 .5

3

3 .3 / 3 .3

3 .4

2 .7 / 2 .7

2 .7

174537**

174927

174945*

3

2 .2

3

4 .6 / 4 .6

4 .7

3 .9 / 3 .9

3 .9

174538**

174928

174946*

5

3 .7

3

7 .1 / 7 .1

7 .3

6 .1 / 6 .1

6 .1

174539**

174929

174549*

7 .5

5 .5

3

10 .5 / 10 .5

10 .7

9 .0 / 9 .0

8 .8

174759**

174553

174556*

10

7 .5

3

12 .5 / 12 .5

12 .8

11 .0 / 11 .0

11 .0

174761**

174559

174763*

15

11

3

19 .3 / 19 .3

19 .7

17 .0 / 17 .0

16 .9

174764**

174562

174766*

20

15

3

25 / 25

25 .4

22 / 22

21 .5

174767**

174564

25

18 .5

3

31 / 31

31 .2

27 / 27

26 .9

174769*

174566

30

22

3

36 / 36

37 .1

32 / 32

31 .9

174597*

174599

40

30

3

47 / 47

47 .5

41 / 41

40 .8

174512*

174594

50

37

3

59 / 59

60 .3

52 / 52

51 .8

174510*

174573

60

45

3

71 / 71

72 .5

62 / 62

61 .7

174575*

NOTE See Section 8 .0 for recommended fuse type .

* = NEMA 4/12 or 12 ENCLOSURE

** = NEMA 4X ENCLOSURE

OTHERS ARE NEMA 1 ENCLOSURE