2 other files, Other files -2 – Yokogawa EJX930A User Manual

Page 142

Advertising
background image

<9. File Format>

9-2

IM 01C25R51-01E

9.2 Other Files

Table 9.2

Other files

Category

File Name

Location

(FSA120 R1.04 or later)

Location

*3

(FSA120 R1.03 or

before)

Flow.

Configuration

Wizard

Automatically

Created

Description

Import

Menu

Export

Menu

Report File *.csv

Desk Top (short cut)
\ [UserName]
\ Documents (Default)

[Windows XP]
Desk Top (short cut)
\ My Documents
(Default)
[Windows Vista]
Desk Top (short cut)
\ [UserName]
\ Documents (Default)

User Flow
Parameters and
Device General
Parameters in CSV
file format.

Obtain
Flow
Coefficient
Log File

EJXMVTool HART:
FlowCoeff.log
(FlowCoeff1.log
(Backup))

*1

<HomeDrive>:
\ YokogawaFlowNavigator

<DTMInstDrive>:
\ Program Files
\ Yokogawa
\ DTMs \ EJXMVTool

Data log of
ObtainFlowCoeff.
Process Value
(DP, SP, ET) Flow
Coefficient (Flow,
Density, Viscosity,
Gas Expansion
Factor, Discharge
Coefficient,
Reynolds No.)

EJXMVTool
F

OUNDATION

fieldbus:
FlowCoeffFF.log
(FlowCoeffFF1.log
(Backup))

*1

<HomeDrive>:
\ YokogawaFlowNavigator

<DTMInstDrive>:
\ Program Files
\ Yokogawa \ DTMs
\ YokFFFramework
\ EJXMVToolFF

*2

Physical
Property
Error Log
File

EJXMVTool HART:
EJXMVTool.log
(EJXMVTool1.log
(Backup))

*1

<HomeDrive>:
\ YokogawaFlowNavigator

<DTMInstDrive>:
\ Program Files
\ Yokogawa \ DTMs
\ EJXMVTool

Physical property
Error Log File

EJXMVTool
F

OUNDATION

fieldbus:
EJXMVToolFF.log
(EJXMVToolFF1.log
(Backup))

*1

<HomeDrive>:
\ YokogawaFlowNavigator

<DTMInstDrive>:
\ Program Files
\ Yokogawa \ DTMs
\ YokFFFramework
\ EJXMVToolFF

*2

DYFMVTool
F

OUNDATION

fieldbus:
DYFMVToolFF.log
(DYFMVToolFF1.
log (Backup))

*1

<HomeDrive>:
\ YokogawaFlowNavigator

<DTMInstDrive>:
\ Program Files
\ Yokogawa \ DTMs
\ YokFFFramework
\ DYFMVToolFF

<HomeDrive>: Drive where users folder exists

<DTMInstDrive>: DTM installed drive

*1:

Log file maximum size is 1 Mbyte per file.

If it exceeds its maximum size, it will be copied to a backup file.

*2:

If you update from FSA120 R1.02.00 or R1.02.01, the log file is saved to the following location.

<DTMInstDrive>:\Program Files\Yokogawa\DTMs\EJXMVTool F

OUNDATION

fieldbus

Version number of EJXMVTool

Software Version

R1.02.00

FieldMate

R1.02.10

Additional Resource Disk

R1.02.00

R1.02.01

FieldMate

R1.02.10

Additional Resource Disk

R1.02.01

*3:

The location where log files are installed is as follows by the difference of Windows XP and Vista.

Windows XP

<DTMInsrDrive>:\Program Files\Yokogawa\DTMs\...

Windows Vista

<HomeDrive>:\Users\[username]AppData\Local\VirtualStore\Program Files\Yokogawa\DTMs\...

Advertising