Removing an Existing Expansion Module

1

Loosen the screws by turning the knobs.

2

Grasp the two knobs one near each side of the front panel, and pull gently but
firmly towards yourself.

3

Insert another expansion module or the blanking plate.

Note:

The Avaya P330 switch must not be operated with the expansion slot open;

the expansion module should be covered with the supplied blanking plate if
necessary.

Note:

X330GT2 Modules are hot swapable and can be inserted or removed in an

operating base unit.

Cabling

A Category 5 copper cable with RJ-45 termination should be used. You should use
all eight wires in the cable.
The maximum copper cable length connected to a 1000Base-T port is 100 m
(328 ft.)