background image

Chapter 3

Avaya P333T Front and Back Panels

10

Avaya P333T User’s Guide

Note:

To perform “Force Initial Version” reset the module and at the same time

press the FIV reset button (use an opened paper clip or other pointed object).
Release the reset buttons first and 1 or 2 seconds later, release the FIV button.

Note:

The Port LEDs of the P333T are numbered from 1-24. Expansion Module ports

are numbered from 51. Port LED numbers 49-50 are reserved.

FC

Flow Control

OFF – No Flow Control

ON – Symmetric/Asymmetric Flow Control
mode is enabled and port is in full duplex
mode.

Hspd

High Speed

10/100

1000

OFF:

10

N/A

ON:

100

1000

LAG

Link Aggregation
Group (Trunking)

OFF – No LAG defined for this port

ON – Port belongs to a LAG

Table 3.2

Avaya P330 <- -> Select buttons

Description

Function

Left/Right

Individual – select LED function (see table above).

Reset module

Press both right and left buttons together for approximately two
seconds. All LEDs on module light up until buttons are
released.

Reset stack

Press both right and left buttons together for 4 seconds. All
LEDs on stack light up until buttons are released.

FIV

Force Initial Version – boot from backup initial version of the
Avaya P330 software, from Bank A (see Note below).

Table 3.1

Avaya P333T LED Descriptions

LED Name

Description

LED Status

Advertising