Configuring insight management integration – HP Integrated Lights-Out 4 User Manual

Page 116

Advertising
background image

Table 10 SNMP traps (continued)

Description

SNMP trap name

Memory errors have been corrected, but the memory module
should be replaced.

cpqHe5CorrMemReplaceMemModule 6064

The fault-tolerant power supply in the specified chassis and bay
reported AC power loss.

cpqHe4FltTolPowerSupplyACpowerloss 6069

The server power has been reset.

cpqSm2ServerReset 9001

The maximum unauthorized login attempt threshold has been
exceeded.

cpqSm2UnauthorizedLoginAttempts 9003

iLO 4 has detected a Self Test Error.

cpqSm2SelfTestError 9005

iLO 4 has detected that the security override jumper has been
toggled to the engaged position.

cpqSm2SecurityOverrideEngaged 9012

iLO 4 has detected that the security override jumper has been
toggled to the disengaged position.

cpqSm2SecurityOverrideDisengaged 9013

The server has been powered on.

cpqSm2ServerPowerOn 9017

The server has been powered off.

cpqSm2ServerPowerOff 9018

A request was made to power on the server, but the server could
not be powered on because of a failure condition.

cpqSm2ServerPowerOnFailure 9019

Generic trap. Verifies that the SNMP configuration, client SNMP
console, and network are operating correctly. You can use the

cpqHo2GenericTrap 11003

iLO web interface to generate this alert to verify receipt of the alert
on the SNMP console.

A power threshold has been exceeded.

cpqHo2PowerThresholdTrap 11018

A change in the health status of the server has occurred.

cpqHoMibHealthStatusArrayChangeTrap 11020

AMS detected a change in the status of an SAS or SATA physical
drive.

cpqSasPhyDrvStatusChange 5022

AMS detected a change in the status of an ATA disk drive.

cpqIdeAtaDiskStatusChange 14004

AMS detected that connectivity was restored to a logical network
adapter.

cpqNic3ConnectivityRestored 18011

AMS detected that the status of a logical network adapter changed
to Failed.

cpqNic3ConnectivityLost 18012

Configuring Insight Management integration

1.

Navigate to the Administration

→Management page.

2.

Click the SNMP Settings tab and scroll to the Insight Management Integration section, as
shown in

Figure 53

).

Figure 53 Editing the Insight Management Integration settings

3.

Configure the HP System Management Homepage (HP SMH) FQDN/IP Address.

This value sets the browser destination of the Insight Agent link on iLO pages.

116

Configuring iLO

Advertising