Hardware and software link-related issues – HP Integrated Lights-Out 4 User Manual

Page 301

Advertising
background image

Table 17 Event log entries (continued)

Description

Event log entry

The system was booted with the Security Override Switch set to On.

Security Override Switch

Setting is On

The system was booted with the Security Override Switch changed from On to
Off.

Security Override Switch

Setting Changed to Off

The on-board clock was set. Displays the previous time or NOT SET if no time
was set.

On-board clock set; was

previously [NOT SET]

The logs are full and the SNMP trap alert failed for a specified IP address.

Logs full SNMP trap alert

failed for: <IP address>

Security was disabled and the SNMP trap alert failed for a specified IP address.

Security disabled SNMP trap

alert failed for: <IP

address>

Security was enabled and the SNMP trap alert failed for a specified IP address.

Security enabled SNMP trap

alert failed for: <IP

address>

An authorized user connected the virtual floppy.

Virtual Floppy connected by

<User>

An authorized user disconnected the virtual floppy.

Virtual Floppy disconnected

by <User>

An authorized user added a license.

License added by: <User>

An authorized user removed a license.

License removed by: <User>

A license activation error occurred.

License activation error by:

<User>

An authorized user logged in to iLO RBSU.

iLO RBSU user login: <User>

A power request was received from one of the following:

Power on request received

by: <Type>

Power Button

Wake On LAN

Automatic Power On

An authorized user clicked the Virtual NMI button.

Virtual NMI selected by:

<User>

An authorized user started a Virtual Serial Port session.

Virtual Serial Port session

started by: <User>

An authorized user stopped a Virtual Serial Port session.

Virtual Serial Port session

stopped by: <User>

A login failure occurred.

Virtual Serial Port session

login failure from: <User>

Hardware and software link-related issues

iLO uses standard Ethernet cabling, which includes CAT 5 UTP with RJ-45 connectors.
Straight-through cabling is necessary for a hardware link to a standard Ethernet hub. Use a crossover
cable for a direct PC connection.

The default DNS name is displayed on the serial number/iLO information pull tab, and can be
used to locate iLO if you do not know the assigned IP address.

If you are using DHCP, the following information applies:

The iLO management port must be connected to a network that is connected to a DHCP server,
and iLO must be on the network before power is applied. DHCP sends a request soon after

Hardware and software link-related issues 301