Disabling alertmail, Configuring remote syslog settings, Enabling ilo remote syslog – HP Integrated Lights-Out 4 User Manual

Page 118

Advertising
background image

3.

Enter the following information:

Email Address—The destination email address for iLO email alerts. This string can be up
to 63 characters and should be in standard email address format. You can enter only
one email address.

Sender Domain—The domain name specified in the sender (From) email address. The
sender email address is formed by using the iLO name as host name, and the subject
string as domain name. If no domain name is specified, the iLO domain name, which
may not be accepted by all SMTP servers, is used. This string can be up to 63 characters.

SMTP Port—The port that the SMTP server will use for unauthenticated SMTP connections.
The default value is 25.

SMTP Server—The IP address or DNS name of the SMTP server or the MSA. This server
cooperates with the MTA to deliver the email. This string can be up to 63 characters.

4.

Optional: Click Send Test AlertMail to send a test message to the configured email address.

This button is available only when AlertMail is enabled.

5.

Click Apply to save the changes.

Disabling AlertMail

1.

Navigate to the Administration

→Management→AlertMail page.

2.

Clear the Enable iLO AlertMail check box.

3.

Click Apply to save the changes.

Configuring Remote Syslog settings

The Remote Syslog feature allows iLO to send event notification messages to Syslog servers. The
iLO firmware Remote Syslog includes the IML and iLO Event Log.

You must have the Configure iLO Settings privilege to change these settings.

This feature and many others are part of an iLO licensing package. For more information about
iLO licensing, see the following website:

http://www.hp.com/go/ilo/licensing

.

Enabling iLO Remote Syslog

1.

Navigate to the Administration

→Management→Remote Syslog page, as shown in

Figure 55

(page 118)

.

Figure 55 Management – Remote Syslog page

118

Configuring iLO