Section 4. Setting up Datalogger Networks

When configuring a TerminalServerPool, use the Terminal Servers tab to add

all the terminal servers that are connected to base modems that can be used to

call this site. The dialing string entered in the phone remote must work in

conjunction with any of the modems connected to the terminal servers added to

the pool for this datalogger.

For more information on modem pooling, refer to LoggerNet’s online help.

When using pooled modems, the modems should all be such that

any of the modems/phone lines could be used in conjunction with

any device that has it as part of its modem pool. Using the same

type – brand of modem is suggested. Also ensure that there is no

preference for phone lines that may be used (e.g. long distance

rates).

Hardware Tab
Standard
Communications Enabled – This check box is used to turn communication on

or off. This check box must be enabled for any communication to take place

over the TerminalServerPool.

Maximum Time On-Line – Enter a time limit for maintaining a connection to

the device. (This may be useful in avoiding costly communication costs, in the

event that a connection to a station is inadvertently maintained for a long

NOTE

4-50