Appendix E. Log Files

TABLE E-1. Transaction Log Messages

Code

Message Text

Message Parameters

Message Meaning

User Response to

Message

15

Starting BMP

data advise

transaction

A start data advise

operation has been

initiated. Data advise

is not in place until

the datalogger

responds.

16

Stopping BMP

data advise

transaction

A stop data advise

operation has been

initiated.

17

BMP data

advise

transaction

started

The message from

the datalogger

confirming the start

of data advise has

been received.

18

BMP data

advise

transaction

stopped

The message from

the datalogger

confirming the

suspension of data

advise has been

received.

19

BMP data

advise

transaction

failed

The attempt to start

or stop a data advise

with the datalogger

has failed or the

operation has timed

out waiting for a

response.

Check communications

with the datalogger by

trying to check the

clock. If that fails

follow the steps for

message 14.

20

Hole detected

Table name; Beginning

record number; Ending

record number

A hole or missed

records has been

detected in the data

coming from the

datalogger.

The server will

automatically try to

collect the data if hole

collection is enabled.

21

Hole collected

Table name; Beginning

record number; Ending

record number

The missing records

specified have been

collected from the

datalogger.

22

Hole lost

Table name; Beginning

record number; Ending

record number

The missing records

have been

overwritten in the

datalogger.

23

Hole collect

start

Table name; Beginning

record number; Ending

record number

The hole collect

request has been

started. This

message won’t go to

the datalogger until

the BMP1 message is

sent. (see message

104)

E-5