Section 5. Real-Time Tools

Function

Description

StdDevOverTimeWithReset

Returns the standard deviation of the specified

value since the function was reset.

Total

Returns the total of all values that it has

considered.

TotalOverTime

Returns the total of all values whose timestamps

are greater than the newest timestamp minus the

specified interval.

TotalOverTimeWithReset Returns the total of all values since the function

was reset.

ValueAtTime

Returns the oldest value in a set of values from a

specified time interval.

5.2.1.5 Remote Connection

RTMC has the ability to connect to LoggerNet software running on another

computer. By default RTMC connects to the computer where it is running, or

the “localhost”.

To set a connection to LoggerNet on another computer, open the server

connection dialog from the Project | Change Server Connection menu item.

The Server Address is the network computer name or IP address. The IP

Address is a number that will have four digits between 0 and 255 separated by

decimal points. An example would be 192.168.4.32. Do not put leading zeros

with the numbers. The default port number for LoggerNet is 6789. If this

default port number is used, it does not need to be specified in RTMC.

Otherwise, it is specified after the server address, separated by a colon. An

example would be 192.168.4.132:3000, where 3000 is LoggerNet’s port

number.

The User Name and Password are only used if you are connecting to a

LoggerNet server that supports security and the network administrator has

implemented security.

Clicking Remember username and password will save the computer address,

username and password as part of the RTMC file so the screen can be run

without requiring the user to know the address or when using RTMC Run-

Time

LoggerNet must be installed with the “Allow Remote

Connections” option enabled for RTMC to be able to connect

remotely.

5.2.2 RTMC Run-Time

The run-time operation allows you to run the real-time graphic display screen

that was created in the developer mode. From the RTMC Development

window you can test the operation of the display screen using the File | Save

NOTE