Section 14. Troubleshooting Guide

Setup Screen, no data will be coming into the data cache. Data Table Monitor

can only display and output data from the data cache. Data Table Monitor

displays and outputs all the data points from an array or table.

Click the Start button to bring up the Start Advise Options dialog. This dialog

gives you choices about which records to display and the data file in which to

store them.

Start Option: This selects the starting point for the data to be displayed and

output to the file.

At Record: This option allows a selection of starting position based on the

file mark and record number. An entry of 0 in both fields will get all of

the data in the data cache.

At Time: This option allows a selection of the starting position based on

the timestamp in the data. The time and date are set in the Begin Date

field. All of the records available after this timestamp are output.

At Newest: This option will set the starting position to the last record

stored in the data cache. This last record and any future records stored will

be output.

After Newest: This option will set the starting position to be the next

record stored in the data cache. Output begins with the next record stored

in the data cache. No historical records will be output.

Relative to Newest: This option starts from the most recent record

collected. The Offset from Newest specifies how much time to go back

from the current write index. For example, an offset of 10 with a setting of

minutes will get the last 10 minutes of data collected.

14-15