Section 7. Creating and Editing Datalogger Programs

The constant SInterval is defined with a default value of 10, a maximum of 60

and a minimum of 5, with a step of 5 each time the up or down control is

selected.

The constant SUnits has a list box with sec and min; sec is the default.

The constant Reps is defined with a default value of 1. It is an edit box, into

which any value can be entered.

The constant Number is defined with a default value of 0, a minimum of -100

and a maximum of 100. The value will increase by 1 each time the up or down

control is selected.

The constant TableName is defined with a list box of “OneSec”, “OneMin”,

“OneHour”, and “OneDay”; the default value is “OneSec”.

Before compiling the program, open the Customize Constants dialog box,

select the constant values you want to compile into the program, and then

perform the Conditional Compile and Save.

7.3.3.9.3 Other Options

Associate Files – This option is used to set up file associations within the

Windows operating system, so that if a program file is double-clicked while in

Windows Explorer, that file with be opened in the CRBasic Editor.

Check one or more boxes for file extension(s) you want to associate and press

the

Associate Files button.

Show Keyboard Shortcuts – This option displays a list of the functions of the

CRBasic Editor which are accessible via the keyboard. The list can be copied

to the clipboard for printing or other uses.

Show Tables – This option displays details about the output tables and the

items they store as they are defined in the current CRBasic program. The list

can be copied to the clipboard for printing or other uses.

Insert Symbol – Opens a dialog box that lets you insert Unicode symbols into

your CRBasic program for use in strings and units declarations.

Set DLD Extension – This option selects which datalogger’s pre-compiler will

be used when performing a pre-compile check on a DLD program which uses

conditional compile statements. A CRBasic program must be named with the

DLD extension for this item to be active.

Open Display Settings File – Opens a previously saved display setting file.

Save Display Settings File – The look and feel of the CRBasic Editor can be

changed from the default. The Font and Background can be changed, as well

as the syntax highlighting. These changes can be saved to a file (with an ini

extension) using the Save Display Settings File menu item. The file can be

reloaded on the same or different computer running CRBasic using the Open

Display Settings File.