Section 8. Working with Data Files on the PC

Typically, the starting time specified must actually be found in the input file

before the Start Condition is satisfied (e.g., if the input file starts at 1100 hrs

and 1000 hrs is entered for the starting time, with no day specified, Split will

skip over arrays until it reaches 1000 hrs the next day). However, the Start-

Stop On/After Time function can be enabled (Output tab, Other button) to

trigger the start of processing when the exact time is found or at the first

instance of data after that time has occurred.

Table-based dataloggers

Because the time stamp for a table-based datalogger is all one string, and

therefore read by Split as one element, the syntax is somewhat different. All

elements in the time stamp are specified by a 1 (if the time stamp is the first

item in each row of data).

The 1s in the string identify the position of the time stamp in the line of data.

Each colon represents a portion of the time stamp. The format is

1[year]:1[day]:1[hour/minute]:1[seconds]. The colons in the time stamp must

be present or the function will not work correctly.

Time synchronization can only be done for data from a single year.

It will not work over a year boundary.

Time elements can be identified without specifying a starting time (e.g., 2:3).

If you are working with only one file, Split will begin processing that file at the

first record in the file. If any gap in the data is found, blank data (or the

“Replace Bad Data With” text) and a carriage return line feed will be inserted

for each line of missing data. Note that Split will also detect a gap in data if,

for instance, you specify a start time of 2[92]:3 (start at Julian day 92) and your

hour/minute for day 92 starts at 9:30 a.m. The time between the start of the

day (0000) and 9:30 a.m. will be considered missing data. Blanks (or the

“Replace bad data with” text) and a carriage return line feed will be inserted at

the beginning of the PRN file for each “missed” output interval.

If you are working with two or more files, once Split starts processing the files

(based on the time of the first record of the first file), if no data exists for the

other file(s), blank data will be inserted.

If multiple input files are given specific starting times, Split starts the output at

the earliest specified starting time. In a PRN file, Blanks or the comment

entered in the “Replace bad data with” field are inserted for values from other

input files until their starting times are reached. In a RPT file only blanks are

used.

When using time synchronization with a mixed array data file,

with a midnight time stamp of 2400, you will need to select the

Other button, “Midnight at 2400 hours” checkbox.