Data files tab (crbasic dataloggers, and, Edlog dataloggers with table data and, Pakbus operating systems) -18 – Campbell Scientific LoggerNet Datalogger Support Software User Manual

Page 74

Advertising
background image

Section 4. Setting up Datalogger Networks

01+0109. 02+2002. 03+0038. 04+1639. 05+15.00 06+13.20 07+24.79 08+073.9

09+269.0 10–1.000

01+0109. 02+2002. 03+0038. 04+1639. 05+25.00 06+13.20 07+24.79 08+073.9

09+279.0 10–.988

01+0109. 02+2002. 03+0038. 04+1639. 05+35.00 06+13.20 07+24.79 08+074.0

09+289.0 10–.946

01+0109. 02+2002. 03+0038. 04+1639. 05+45.00 06+13.20 07+24.79 08+074.0

09+299.0 10–.875

01+0109. 02+2002. 03+0038. 04+1639. 05+55.00 06+13.20 07+24.79 08+074.0

09+309.0 10–.777

01+0112. 02+2002. 03+0038. 04+1640. 05+0.000 06+13.20 07+24.79 08+074.0

09+074.1 10+1638. 11+18.00 12+13.19

01+0109. 02+2002. 03+0038. 04+1640. 05+5.000 06+13.20 07+24.78 08+074.0

09+319.0 10–.656

Binary writes the data to a file in a binary format. The advantage of the

binary format is that it is more compact so the size of the file is much

smaller than for the ASCII based files. The disadvantage is that it’s

unreadable except using View or by post-processing with Split.

Collect Mode – The collect mode allows you to choose how much data to

collect when getting data from the datalogger.

Data Logged Since Last Collection – When LoggerNet calls the

datalogger to collect data, it will try to get all of the data stored by the

datalogger since the previous call. If this is the first call to a datalogger

there might be a lot of historical data stored. When Collect All on First

Collection is checked, LoggerNet will collect all data in the datalogger the

first time data is collected. If Collect All on First Collection is not

checked, the first call to the datalogger will collect the number of arrays

specified in the Arrays to Collect on First Collection field. This allows

you to avoid keeping communications tied up while all the historical data

is collected.

Most Recently Logged Arrays – This option is used when you are

interested in only the most recently stored data. When this option is

selected you can specify how many arrays back from the most recent array

should be included when data is collected from the datalogger.

4.2.4.4.4 Data Files Tab (CRBasic Dataloggers, and Edlog Dataloggers with Table Data

and PakBus Operating systems)

Table-based dataloggers include the CR10T, CR510TD, CR10X-TD,

CR23X-TD, CR1000, CR800 Series, CR3000, CR5000, CR9000, and CR200

Series. Data output to final storage is stored as records in tables. The Data

Files tab is used to define what data tables will be collected from the

datalogger, along with the output file name and format.

Tables to be Collected – All of the available tables in the datalogger are listed

in the column on the left. If no tables are listed, click the Get Table Definitions

button. The tables selected for collection are shown with a green check mark

and the excluded tables are shown with a red ‘X’. Data from the selected

tables will be collected from the datalogger during scheduled data collection.

4-18

Advertising